KSB Evamatic Box installation instructions![]() These operating instructions contain fundamental information and precautionary notes. It is imperative to read the manual prior to installation of unit, electrical connection and commissioning. Operating instructions relating to individual components of this unit must also be complied with. Prior to any work carried out on the pump set, disconnect it from the all electrical supplies (including control cable) and/or remove the mains plug. The pump set must be protected against accidental start–up. Contents 1. General. 2. Frost–proof Installation. 3. Description. 3.1 Evamatic Box single pumping station 3.2 Evamatic Box double pumping station 4. Installation of the Plastic Tank. 4.1 Floor installation 4.2 Underfloor installation 5. Installing the Pump(s) in the Tank. 5.1 Evamatic Box single pumping station 5.2 Evamatic Box double pumping station 6. Connection to Power Supply. 7. Dimensions. 7.1 Evamatic Box single pumping station 7.2 Evamatic Box double pumping station 8. Accessories. 8.1 Check valve with shut–off made of cast iron / galvanized steel 8.2 PVC check valve and PVC check valve with shut–off 8.3 Hand pump 8.4 AS 0 Alarm switchgear 8.5 Cover extension piece 9. Automatic Operating Mode. 1. General Safety Instructions for Maintenance, Inspection and Installation Work The entire plant must comply with the requirements of the standard EN 12050. The operator must take care that all maintenance, inspection and installation work is done by fully qualified and authorized personnel which must carefully study these operating instructions prior to the performance of this work. As a general rule, work on the equipment must be carried out only during standstill. Please observe all instructions set out in the chapter ”Commissioning” (see Operating instructions Pump) before returning the machine to service. The sewage lifting unit and its components must be inspected and maintained at least once a year. Systematically disconnect all electrical connections prior to work on the station or the pumps. For maintenance work, the pump(s) must be taken out of the tank. Access to the tank The following safety instructions must be adhered to without fail before climbing into the tank! 2. Frost–proof installation ![]() ![]() ![]() ![]() ![]() ![]() ![]() 6. Connection to power supply Single pumping stations The single–phase pump sets are supplied complete with power supply cable and mains plug. Double pumping stations The three–phase pump sets do not come with a mains switch. Remove the protection on the cable end shortly before connection to power supply. The individual cores are marked at the end of the cable. If the cables have to be shortened, please note the markings and/or colours of the cores. Twin pumping stations are connected in the control cabinet (switchgear). ![]() ![]() ![]() 8. Accessories. ![]() ![]() ![]() ![]() ![]() ![]() 9. Automatic operating mode ![]() |
|
| Copyright © Drainstore 2008. Web design by 7Soft.co.uk Units 1 & 2 , Heanor Gate Road , Heanor Gate Industrial Park , Heanor , Derbyshire, DE75 7RJ, United Kingdom Show Map |